LONG TERM HEMODIALYSIS CATHETERS Pediatric Split Cath® Split Cath® III Split Stream® Tesio® Titan HD Hemo-Flow® Hemo-Flow® XF Hemo-Cath® LT Symetrex® HEMO-CATH® LT Indications for Use: The Medcomp® Hemo-Cath® LT Silicone Double Lumen Catheter can be utilized for long term implantation as well as temporary access for hemodialysis, hemoperfusion, or apheresis therapy. The cannula may be inser ted via the Seldinger Technique due to the inner Teflon stylet, increasing linear strength. The stylet is removed after inser tion, leaving the soft silicone cannula in the body. The flexible silicone make-up conforms well to the vessel anatomy, resulting in higher patient tolerance during extended use. Contraindications: The Subclavian Approach is NOT recommended for use with the Medcomp® Double Lumen Subclavian-Femoral Catheter in Hemodialysis or Hemoperfusion Procedures used for the management of acute poisoning or other situations in which a ventilator might be used due to risk of traumatic pneumothorax posing a dangerous complication for the patient. SYMETREX®/SYMETREX® WITH SIDEHOLES Indications for Use: The Symetrex® Long Term Hemodialysis Catheter and the Symetrex® Long Term Hemodialysis Catheter with Sideholes are symmetric tip dual lumen catheters designed for chronic hemodialysis and apheresis. They may be inser ted percutaneously or by cut down. Catheters with greater than 37 cm implant length are indicated for femoral placement. Contraindications: Do not use these catheters in thrombosed vessels or for subclavian puncture when ventilator is in use. These devices are contraindicated whenever: Used for any purpose other than indicated in these instructions. The presence of other device related infection, or septicemia is known or suspected. End caps are not intended to be punctured with a needle. Severe chronic obstructive lung disease is present. Tissue factors in the localized area of device placement will prevent proper device stabilization and/or access. Venous thrombosis or vascular surgical procedures have occurred at the prospective placement site. Post irradiation of prospective inser tion site. TESIO® REPAIR KIT Indications for Use: The Medcomp® Tesio® Catheter is designed for Long Term Hemodialysis and Apheresis. It may be inser ted percutaneously, and is ideally placed in the internal jugular vein. Although this catheter may be inser ted into the subclavian vein, the internal jugular vein is the preferred site. Contraindications: This extension is not intended for any use other than that which is indicated. To maintain peak performance of the extension, it is recommended that the extensions be replaced every 6 months. SPLIT STREAM® REPAIR KIT Indications for Use: Repairs MedComp® Split Stream® Catheters Contraindications: This catheter is intended for Long-Term vascular access only and should NOT be used for any purpose other than indicated in these instructions. To maintain peak performance of the Split-Stream® extension set, it is recommended that the extension set be replaced every 6 months. MEDCOMP® REPAIR KIT Indications for Use: The Medcomp® Repair Kit is indicated for use in replacing damaged female luer connectors, clamps, or repairing extensions where there is a minimum of 4.5cm viable extension tubing. Repairs Medcomp® Catheters: Split Cath® Contraindications: Do not use to repair catheters other than those specified above. Do not replace connector if tubing is swollen or displays signs of degradation. This repair kit should not be used for any purpose other than indicated in these instructions. Refer to Instructions for Use provided with the product for complete instructions, warnings, precautions, and contraindications. Observe all instructions for use prior to using products. Failure to do so may result in patient complications. 6 Long Term

RkJQdWJsaXNoZXIy MTYyNDM3Mw==