Medcomp Domestic Catalog

SHORT TERM HEMODIALYSIS CATHETERS SLX Duo-Split® Hemo-Cath® ST Duo-Flow® 400XL Duo-Flow® Duo-Flow® Side x Side Duo-Flow® Soft-Line® T-3® CT Tri-Flow Trio-CT® DUO-FLOW® SOFT-LINE® Indications for Use: The Medcomp® Duo-Flow® Soft-Line® and Raulerson/Duo-Flow® Double Lumen Internal Jugular Catheters are designed for acute hemodialysis and apheresis. They may be inser ted percutaneously and are ideally placed in the jugular vein. Contraindications: This catheter is not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. T-3® CT Indications for Use: The Medcomp® T-3® CT Catheter is a triple lumen catheter indicated for use in attaining shor t-term vascular access for hemodialysis, apheresis. The third internal lumen is intended for infusion, power injection of contrast media and central venous pressure monitoring. The catheter is intended to be inser ted in the jugular, femoral or subclavian vein as required. The maximum recommended infusion rate is 5ml/sec for power injection of contrast media. Contraindications: This catheter is intended for shor t-term (less than 30 days) vascular access only and should not be used for any purpose other than indicated in these instructions. This device is also contraindicated: When the presence of device related infection, bacteremia, or septicemia is known or suspected. When the patient’s body size is insufficient to accommodate the size of the implanted device. When the patient is known or is suspected to be allergic to materials contained in the device. If the prospective inser tion site has been previously irradiated. If the prospective placement site has previously suffered episodes of venous thrombosis or vascular surgical procedures. If local tissue factors may prevent proper device stabilization and/or access. TRI-FLOW Indications for Use: The 12F Tri-Flow Triple Lumen Catheter is indicated for use in attaining Shor t-Term vascular access for Hemodialysis and Apheresis. It may be inser ted percutaneously and is primarily placed in the internal jugular vein of an adult patient. Alternate inser tion sites include subclavian vein or femoral vein as required. The 12F Tri-Flow Triple Lumen Catheter is intended to be used less than (30) days. Contraindications: This catheter is intended for Shor t-Term vascular access only and should not be used for any purpose other than indicated in these instructions. Do not inser t catheter in thrombosed vessels. TRIO-CT® Indications for Use: The Trio-CT® Triple Lumen Catheter is indicated for use in attaining shor t-term (less than 30 days) vascular access for hemodialysis and apheresis. The third internal lumen is intended for infusion, power injection of contrast media and central venous pressure monitoring. The catheter is intended to be inser ted in the jugular, femoral or subclavian vein as required. The maximum recommended infusion rate is 5ml/sec for power injection of contrast media. Contraindications: This catheter is intended for shor t-term (less than 30 days) vascular access only and should not be used for any purpose other than indicated in these instructions. This device is also contraindicated: When the presence of device related infection, bacteremia, or septicemia is known or suspected. When the patient’s body size is insufficient to accommodate the size of the implanted device. When the patient is known or is suspected to be allergic to materials contained in the device. If the prospective inser tion site has been previously irradiated. If the prospective placement site has previously suffered episodes of venous thrombosis or vascular surgical procedures. If local tissue factors may prevent proper device stabilization and/or access. Refer to Instructions for Use provided with the product for complete instructions, warnings, precautions, and contraindications. Observe all instructions for use prior to using products. Failure to do so may result in patient complications. 16 Shor t Term

RkJQdWJsaXNoZXIy MTYyNDM3Mw==